for common settings of 8 data bits, 1 stop bit, no parity and the following baud rates, set P7013 to the values from this table.
Baud | P7013 |
2400 | 33544 |
4800 | 33552 |
9600 | 33568 |
19200 | 33600 |
38400 | 33664 |
For any other settings, use this table
Baud rate Field Selection | Bit Index | Selects the baud rate when the Autobaud Detect function is disabled. |
Bit Description | ||
Baud rate Bit 0 | 0 | |
Baud Rate Bit 1 | 1 | |
Baud Rate Bit 2 | 2 | |
Baud Rate Bit 3 | 3 | |
Baud Rate Bit 4 | 4 | |
Baud Rate Bit 5 | 5 | |
Baud Rate Bit 6 | 6 | |
Baud Rate Bit 7 | 7 | |
Data bits Control Fields |
| Selects the number of data bits transmitted as follows: |
Data bits Bit 0 | 8 | |
Data bits Bit 1 | 9 | |
Stop bits Control Fields |
| Selects the number of stop bits as follows: |
Stop bits | 10 | |
Parity Bits Control Fields |
| Selects the parity as follows: |
Parity Bit 0 | 11 | |
Parity Bit 1 | 12 | |
Reserved | 13 | |
Reserved | 14 | |
Startup Enable Control Fields |
| Enables / disables the Autobaud Detect feature |
Startup Enable | 15 |
23-mar-2012 jw