in addition to C171 three other parameters are required for BiSS set-up.
Parameter | Description |
---|---|
C168 | Number of valid bits= single turn + multi turn |
C179 | Set-up value |
C180 | Multi-turn value |
These parameters are included as part of the motor file download in ACR-View for the following Parker motors.
Parameter | C168 | C179 | C180 |
---|---|---|---|
Description | valid bits | Set-up value | Multi-turn value |
PM-FAL w/o battery | 34 | 37752853 | 65535 |
PM-FBL w/o battery | 35 | 37752853 | 65535 |
PM-FCL w/o battery | 35 | 37752853 | 65535 |
PM-DD | 20 | 41943061 | 1 |
MX80L | 26 | 33554458 | 1 |
PM-FAL w/ battery | 34 | 33558549 | 65535 |
PM-FBL w/ battery | 35 | 33558549 | 65535 |
PM-FCL w/ battery | 35 | 33558549 | 65535 |
BiSS ENCODER PIN-OUT
IPA Pin | BiSS Function | P Encoder cable Wire |
---|---|---|
1 | SLO | WHITE |
2 | /SLO | WHITE w/black |
3 | Encoder power return | ORANGE w/black |
4 | +5 VDC Encoder power | ORANGE |
9 | MA | yellow |
13 | /MA | yellow w/black |
Pre-made cables are available for IPA and P Series motors:
...