Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

There are two possible resolution settings for Interact Applications.

MOST 5 and 6 inch displays are Quarter VGA (320x240) but there have been some part numbers over the years that were 6 inch but VGA (640x480) resolution.

Units 8 inches and larger displays are all 640x480 resolution.

You can change from 8 to 10 or from 10 to 15 or 15 to 8 inch units and the application fills the screen since all of the displays are 640x480 regardless of physical dimensions.

The 6 inch units had both so knowing which one you have is critical. We require the full part number of the old unit so we can tell you the correct replacement.

Starts with          Resolution          Replaced By           Alternate

P11-xxxxx          320x240              P1306QT-Qx          PA206Q-13x

P12-3xxxx          320x240              P1306QT-Qx          PA206Q-13x

P12-4xxxx          640x480              P1306VT-Qx           PA206V-13x

NOTE: Alternate Replacement using PA2 requires mod to hole size in panel. Not drop in.

Check user guides for cutout dimensions.

These are basically MSDOS PCs and they have a FIXED resolution

...

. There are two options to resolve this:

  1. Create a new application using the updated resolution settings and recreate each panel.

  2. Open the application - in the settings there is an option to set the resolution. Change the setting here to the updated resolution. Manually stretch (drag and drop) each graphic object on the screen to match new scale.

image-20241125-175820.pngImage Added
image-20241125-180717.pngImage Added

Replacing units with different resolutions will result in screens that look like the images below:

320x240 application running on 640x480 display

...

2402_pastedimage1561568349856v_5176-20240521-001008.pngImage Added

640x480 application running on a 320x240 display.

...

...

3364_pastedimage1561568444864v_5177-20240521-001008.pngImage Added