Cables
Both of these cables can be purchased through your local Parker Distributor or Integrator. See the following sections to determine what cable is required to communicate to your drive.
CM351909 has, on one end, an "RJ" connector that connects into the drive. The other end terminates into an RS232 connector via a provided RJ to Serial converter.
If your computer/laptop does not have a serial port you will need to supply your own USB-to-Serial adapter. We recommend FTDI chip based adapters. Prolific Prolific chipsets will not work.
...
CM471050 is a MiniUSB cable.
It can be used to program LINKnet techboxes and communicate to an 890 drive
...
Software Summary Matrix
Software for Standalone Drives
...
590, 590+, 650, 650V, 650G or 690+:
You will need the CM351909 programming cable
590C or 590D Connect/Install/Extract with DSELite [For 590+ product migration]
AC890
You will need a MiniUSB cable. Parker offers part number CM471050.
AC30
You will need a standard CAT5 or CAT6 ethernet cable.
Additional information in the AC30 subsection below. Please Read.
AC20
You will need a standard CAT5 or CAT6 ethernet cable.
AC15
You will need a standard CAT5 or CAT6 ethernet cable.
AC10
You will need a USB-RS485 Serial converter or the dedicated 1002-00-00 module.
The dedicated 1002-00-00 module for the AC10 is recommended. Can be purchased from a local distributor/integrator
If using a basic USB – RS485 Converter we recommend US Converters' Part Number XS885
Software for LINKnet Systems, or Firewire Systems
...
For the PDQ software you will likely use, see the link at the top of this FAQ page for download.
A standalone software package based on Codesys - utilizing function chart based aspects of Codesys (very similar to DSELite)
Ensure your IP address on the PC has the same subnet as the base AC30.
For PDD see the associated FAQ for install/update instructions, and connecting to the AC30 in the PAM environment.
A software package integrated into the Parker Automation Manager software (to utilize full PLC functionalities in a Codesys coding environment)
A version comes standard with PAM1.4
For DSELite, if you want or have a LinkNet AC30 you must connect with DSELite to interface with the drive.
Used out of the box for all AC30 drives
If your AC30 has two versions of firmware located on the 3rd line down on the main menu of the keypad, you have a LinkNet firmware drive and it requires DSELite.
If you want LinkNet, follow the Help file in DSELite to connect to the drive and do a Command -> Install AC30 Firmware.
...
DSD-RUN is just the runtime version of the software which will allow you to upload and download programs onto LINK Techboxes, LINK Racks, etc. -- (CM351909 comes included)
All Diagnostic & Maintenance Functions
DSD-DEV will give you all the functionality of DSD-RUN plus the ability to program the projects. -- (CM351909 comes included)
All Diagnostic & Maintenance Functions, Create new Projects &/or add Modules
14JUN2016 LS
8/29/2018 SV
20Jul19 JD
...