The Dynaserv motors uses IKO crossed-roller bearings. These bearings are capable of taking such complex loads as radial, thrust and moment loads at the same time. They are widely employed in industrial machines, industrial robots, medical apparatus, etc.

DYNASERV BEARING SPECIFICATIONS

Specification/Unit

DM-B

DM-A/DR-A

DR-E

DR-B

Inner Diameter/mm

90

190

120

106

Outer Diameter/mm

130

240

180

140

Average Diameter/mm

110

215

150

123

Thickness/mm

16

24

25

16

Basic Dynamic Load Rating/kgf

1500

4350

5080

2050

Basic Static Load Rating/kgf

2440

8300

7610

2440

Pre-Load/kgf

305

595

439

288

Static Axial(Compression) Load Permitted/kgf

3000

4000

4000

3000

Static Axial(Tension) Load Permitted/kgf

1000

2000

2000

1000

Static Over Hung Load/kgfm

20

40

40

20

Axial(Compression) Stiffness/mm/kgf

.000025

.00002

.00002

.00003

Axial(Tension) Stiffness/mm/kgf

.00003

.00003

.00003

.00004

Over Hung Load Stiffness/rad/kgfm

.00001

.000004

.000004

.00002