Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Current »

AR-20 and AR-30 drives are no longer available and are no longer repairable. We recommend discussing the belows options and the application machine requirements with your local Parker Automation Technology (ATC) distributor. They've automation engineers factory trained on our products and will be able to review your application specifics to determine the best choice moving forward.

Suggested Replacements
While the Aries AR-20 and AR-30 does not have a direct replacement, there are several products that are suitable depending on the application requirements. The Aries was designed to fit many different machine control solutions with a wide array of features. Not every feature is needed for every application so in order to select a replacement, the current installation should be reviewed in detail. The check list on the following page compares key specifications and features of the AR-20 or AR-30 with recommended Parker drives.

P Series: PD-35P exceeds the motor output requirements of the AR-20 and AR-30, has a smaller footprint and is the cost effective and in stock solution.

Compax3: S150V2F12I10T0M00 exceeds the motor output requirements of the AR-20 and has the most features and flexibility. It may work as a replacement for the AR-30AE depending upon the continuous/peak torque required by the motor in the machine application. The S300V4F12I10T10M00 exceeds the motor output for the AR-30AE but is physically much larger.

Click here to view below chart as Adobe Acrobat (.pdf)

Product

AR-20AE

AR-20SE

AR-30AE

AR-30SE

PD-35P

S150V2

S300V4

Continuous Current (RMS)

10

10

16

16

16.7

15

30

Peak Current (RMS)

30

30

48

48

50

30

60

Mains Input Voltage

240VAC 1phase

Yes

Yes

No

No

Yes

No

No

240VAC 3phase

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Control Power Input

240VAC 1phase

Yes

Yes

Yes

Yes

Yes

No - 24vdc

No - 24vdc

Modes of Operation

Torque

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Velocity

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Position

No

Yes

No

Yes

Yes

Yes

Yes

Command Input

+/-10 VDC Analog Resolution

14 bit

14 bit

14 bit

14 bit

12 bit

14 bit

14 bit

Step & Direction, 5V

No

Yes

No

Yes

Yes

Yes

Yes

Motor Feedback Support

Quad Encoder w/halls

Yes

Yes

Yes

Yes

Yes

Yes

Yes

EnDat 2.1

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Q/3E smart incremental

Yes

Yes

Yes

Yes

No*

No*

No*

I/O

Connector

26pin HD

26pin HD

50pin HD

15pin HDx2

Enable Input

5-24VDC

5-24VDC

12-24VDC

24VDC

24VDC

Reset Input 

5-24VDC

5-24VDC

24VDC

24VDC

Fault Output

5-24VDC

5-24VDC

24VDC

24VDC

Brake output

Built-in Relay

Built-in Relay

Output only

Powered Directly

Encoder Output

Pass-thru

Yes

Yes

Yes

Yes

No

Yes

Yes

Simulated

No

No

No

No

Yes

Yes

Yes

SSI (with EnDat2.1)

Yes

Yes

Yes

Yes

No

No

No

Feedback cable PS Motors

Quad Encoder w/halls

F-1A1

F-1A1

F-4A1

F-2C1

F-2C1

EnDat 2.1

F-1A2

F-1A2

F-4A2

F-2A2

F-2A2

Drive to Controller Cables

to ACR9000

71-021599

71-021599

71-032478

71-021108

to 6K

71-021600

71-021600

n/a

71-021625

PC Communications 

RS232 with dongle

RS232 with dongle

USB

RS232**

RS232**

Dimensions, mm

Height

267

267

169

273

412

Width

119

119

88

158

175

Depth

171

171

198

172

172

  • Pseries and Compax3 do support hall-less startup. Standard motor file can be adjusted. Email

emn.service@support.parker.com for further details with motor part number.

**Compax3 can be purchased with Ethernet TCP/IP communications with I30T11 option:  S150V2F12I30T11M00  OR S300V4F12I30T11M00

Motors and Feedback
The P Series and Compax3 will support most of the motors that are used with the AR-20. The key exception is the obsolete Parker smart encoders. These encoders were designated by the order code of “3E” in the MPP/MPJ series and by “Q” in all other motor families. The Parker smart encoders were 2000 line, incremental encoders that store motor set-up information in the encoder and push this data to the Aries on start-up. This data included initial hall/encoder alignment information. The P Series and Compax3 cannot read this information and therefore would not be able to use the hall information for initial commutation. In some applications it may be appropriate to keep these motors and run the drives in hall-less commutation mode.

Both the P Series and Compax3 can use Endat2.1 encoder which are designated by the order code of “6D”, “7D”, “8D” and “9D” in the MPP/MPJ motor families. When using one these motors with the Aries, the encoder output from the drive to the controller is in SSI format. Neither the Compax3 nor the P Series can produce an SSI signal for the encoder output. Some changes would be required to the controller program to accommodate the incoming encoder signal from the drive.

Cables
Feedback cable connectors and pin-outs are different for each drive. When changing from an Aries to Compax3 or P Series it will be necessary to change to a new feedback cable per the chart above or to rework the connector.

Both the Compax3 and the P Series offer equivalent I/O for interfacing with a controller, but the drive side connectors and pin-outs are different. The chart above references cables sets for popular Parker controllers to the drives.

Keywords: AR20AE, AR30AE, AR20SE, AR30SE, AR20-AE, AR30-AE, AR20-SE, AR30-SE, Airies

  • No labels

0 Comments

You are not logged in. Any changes you make will be marked as anonymous. You may want to Log In if you already have an account.