We have several FAQ's in the sidebar to get your AC10 motor startup running and the quickstart guide can also be ran through to achieve motion on your motor. This FAQ is designated a quick check-list to determine a general cause for the motor not running during a startup or existing application.

  1. Have you verified the wiring connections?

  2. Is F208 set for the correct START/STOP function?

  3. Is External Coast Stop TRUE?

  4. Is Free Stop TRUE?

  5. Is Enable TRUE?

  6. Is the inverter going into Current Limit?

  7. Can you spin the shaft of the motor using your hand?

  8. What type of device is controlling the speed input? (potentiometer, Keypad, sensor)

  9. What is the control mode? (V/Hz, Sensorless Vector)

  10. Will the drive work using the keypad-only settings?

  11. Will the drive work in V/Hz control mode?

  12. Using the keypad Running Display (other values can be added with F131)

    1. Verify the following while the drive is enabled to run:

      • Output Speed Reference: _____ (FRQ LED lit)

      • Output RPM: _____

      • Output Current: A _____

      • Output Voltage: U _____

      • DC LINK VOLTS: u _____