Can I Use Aries Drives with MX80L Linear Motor Stages?

Can I Use Aries Drives with MX80L Linear Motor Stages?

AriesCE (Controller version): Yes
AriesPE (Powerlink Version): Yes
AriesAE (Analog Command Input): No
AriesSE (Step/Direction Command Input): No

 

The Aries Controller (and Aries Powerlink) drives can operate with a motor input power as low as 45VDC, making it suitable for driving the MX80L motors. No firmware or hardware modifications are required. AriesAE/SE versions cannot run below ~90VDC therefore are not compatible with the MX80L.

 

 

MX80L Linear motors stages require a maximum bus voltage of 80VDC and are typically used with ViX Servo drives. The AriesCE/PE is generally specified for motor input power of 120-240VAC, which results in a bus voltage of ~170-340VDC. If a bus voltage of 100+ was applied to the MX80, damage would occur to the motor. However, the existing design of the Aries CE/PE supports direct input of DC voltage as low as 45VDC. The MX80L motors typically utilize 48-80VDC.

 

The Aries also requires Control Input Power of 120/240VAC. This cannot operate as low as the motor power input and should remain at 120/240VAC. Be sure to remove the factory installed jumpers on the power connector.

 

The XL-PSU power supply can be used to provide the 80VDC motor power to the drive.

 

The 15-pin feedback connector in the MX80L plugs directly into the Aries without modification.

 

Motor files for MX80L are not included in ACR-View, but are available here.

 

ariesce_mx80l_4577-20240521-000855.jpg

 

ariespower_mx80_4578-20240521-000855.jpg

 

ariesce_mx80l_limit_4162-20240521-000855.jpg

 

 

Jan-16-2012  JW