6K Software - Does a !K Command Stop a PLC Program?
6K Software - Does a !K Command Stop a PLC Program?
A PLC program does stop executing when the !K (immediate Kill) command is issued. A Kill input (INFNC-C) does not stop the PLC execution.
Neither the !S command or Stop input (INFNC-D) stop PLC execution.