Trilogy High Flex Cable Specifications

THF series high flex cables have been improved.

  • The cables meet UL requirements and have a uR mark.

  • Green/yellow safety earth ground wire wire added in accordance with EN60204.

  • Outer diameter increases on all cables.

  • All motor phase wires now have a yellow stripe. One motor power wire color changes and some wire gaurges changed.

The Iforce motors use different cables for the different WD wiring option for the coil.  The "THFxx" name in the tables below is the identification numbers for the cables; this number is also printed on the jacket of each cable:

thf_single_5011-20240521-001120.png

 

Example: Coil part number is 210-3A-NC-WD2S-8

210 coil with WD2 wiring option:  uses THF08 cable per chart above

 

thf_dual_5012-20240521-001120.png

 

These improvements were announced on Technical Change bulletin 452 (May 2008) and also as the IForce motors changed (TC 456, 458, 463, 469, 501, 506, 523, 526). Cable improvements changed at these times:

 

Cable

Product

Change Date

THF05

R7, R10, R16, ML50

Sept 1,2008

 

410

Aug 4,2008

THF08

310

Dec 17,2008

 

210

July 8,2009

 

110, Cable Only

Aug 19,2009

THF10

110, 210, 310, Cable Only

Feb 19,2010

THF06

210 WD7, 310 WD7, 410 WD3, 410 WD4

Nov 10,2008

THF15

MHED, Ripped MHED

Apr 1,2010

 

 

New Cable specs:

 

Cable

Specs

THF15

Meets RoHS compliance, marked on jacket

 

Light green changed to light green with white stripe

 

UR marked on jacket

 

Diameter: .230-in

 

13 28AWG conductors plus 1 28AWG drain, 1 pair 26AWG twisted conductors

 

UL AWM 2586 105C, 600V

 

 

THF08

Meets RoHS compliance, marked on jacket

 

UR marked on jacket

 

Diameter increased from .22-in to .235-in

 

20AWG Green with yellow stripe added

 

Yellow stripe added to motor conductors

 

6 24AWG conductors plus 1 20AWG, 1 pair 28AWG twisted conductors

 

UL AWM 2586 105C, 600V

 

 

THF10

Meets RoHS compliance, marked on jacket

 

UR marked on jacket

 

Diameter increased from .228-in to .281-in

 

20AWG Green with yellow stripe added

 

Yellow stripe added to motor conductors

 

7 28AWG conductors with 24AWG drain wire, 4 20AWG conductors

 

UL AWM 2586 105C, 600V

 

 

THF06

Meets RoHS compliance, marked on jacket

 

UR marked on jacket

 

Diameter increased from .155-in to  .181-in

 

6 26AWG conductors with 26AWG drain wire

 

UL AWM 2586 105C, 600V

 

 

THF05

Meets RoHS compliance, marked on jacket

 

UR marked on jacket

 

Diameter increased from .237-in to .267-in

 

18AWG Green with yellow stripe added

 

Yellow stripe added to motor (Red,Brown,Orange) conductors

 

4 18AWG conductors with 24AWG drain wire, 1pair 28AWG twisted conductors

 

UL AWM 2586 105C, 600V

 

Old Cable specs:

Votage Rating 400VDC Cont 
Conductor Insulation FEP rated @ 250 degree C 
Cable Overall Insulation PVC rated @ 105 degree C 
Current Rating Current determined by cable temperature rating and continuous motor current 
Minimum Bend Radius >5 diameters for rolling flexure in cable track

 

 

Part No.

Total # of Conductors

Diameter

#

AWG (mm)

#

AWG (mm)

THF01

1

.095"

1

16 (1.29)

-

-

THF05

5

.260"

3

18 (1.02)

2

24 (0.511)

THF06

6

.125"

6

26 (0.405)

-

-

THF08

8

.195"

6

24 (0.511)

2

28 (0.321)

THF08E

8

.175"

8

26 (0.405)

-

-

 

 

 

Part No.

Total # of Conductors

Diameter

#

AWG (mm)

#

AWG (mm)

THF10

10

.200"

3

24 (0.511)

7

28 (0.321)

THF15

15

.200"

2

26 (0.405)

13

28 (0.321)