Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Related FAQ: Can the Compax3 be used at 24volts? Or other dc voltage? (with video)

Yes. All Compax and Compax3 products can take a DC voltage instead of AC voltage input. All drives rated for 240 V input can be supplied up to 340 VDC and all drives rated for 480 V input can be supplied up to 680 VDC.

For the CPX1000SL, 2500S and C3 xxxx V2 products use the following installation connections.

CPX1000SL

CPX2500S

C3 xxxx V2

DC +

X2/1 L

X2/1 L1

X1/1 L

DC -

X2/2 N

X2/2 L2

X1/2 N

PE

X2/3 PE

X2/3 PE

X1/3 PE

For the CPX4500S, 8500S, NMD10, NMD20 and C3 xxxx V4 products use the following installations connections.

CPX4500S/8500S

NMD10/20

C3 xxxx V4

DC +

X2/1 L1

X2/1 L1

X2/4 +HV

DC -

X2/2 L2

X2/2 L2

X2/5 -HV

PE

X2/3 PE

X2/3 PE

X2/3 PE

For the C3S running on DC power, the internal mains filter has no function, so ensure that the DC power supply includes a DC filter. When the DC voltage is connected to X2, the drive can be supplied up to 680V without any derating. Otherwise, connecting to X1 (using L1 and L2 instead of +HV and -HV) the maximum allowed DC voltage is max 500V. The Compax3's overvoltage protection and regenerative circuitry is active when powering through either X1 and X2.