Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Current »

This FAQ allows the user to setup Option 1 Encoder motors with software changes. Option 1 Encoder motors can also be setup through software changes. Please see "ViX - (MPM) Encoder Option 1 Software Setup."
The following is a table for the MaxPlus (MPM) Encoder Option 1 Termination to ViX Connections:

Feedback Connections

ViX Feedback Connector X2

Option 1 Encoder Cable (175-0xxx)***

Wire Function

Pin#

Pin Letter

Function

GND

3

T

GND

+5 VDC output

5

K

+5VDC

incremental enc.A+

8

C

CH A\

incremental enc.A-

7

B

CH A

incremental enc.B+

12

N

CH B

incremental enc.B-

11

P

CH B\

incremental enc.Z+

1

M

CH Z

incremental enc.Z-

2

U

CH Z\

Commutation f-b A0

9

E

CH U

None*

N.C.*

R

CH U\

Commutation f-b A1

13

F

CH V

Commutation f-b A2

14

G

CH W

None*

N.C.*

S

CH U\

None*

N.C.*

H

CH W\

Connector Housing**

**

D

Gnd/Cable

Drain

Motor overtemp+

10

A

THERM

Motor overtemp-

6

L

THERM

Connector Housing**

**

J

SHLD

Motor Power Connections

ViX Motor Power Screw Terminals

Option 1 Motor Power Cable

X1 Function

Phase

Pin Letter

Function

Wire Color

Phase U

U

A

Phase R

Red

Phase V

V

C

Phase T

Blue

Phase W

W

B

Phase S

Black

Ground

GND

D

PE GND

*The Hall signals on the MPM motors are diffential, therefore, you do not need to connect the negative signals of each hall state to the single-ended ViX Hall signals.
**The shield connections of the feedback cable should be connected to the ViX X2 header's metal housing (if possible).
*** Option 1 encoder cable wire colors can vary, however, the wire function should be consistent among all cables. If your cable wire marker (labels) are no longer present or readable, please contact Parker.

  • No labels