The encoder resolution range of the OEM070 is from 400 to 65532. With this ER set to 63488 - exactly 1/8 of the Dynaserv (507904) - a roundoff error will occur.
This error manifests itself as a noticeable drift in motor position after several moves. The solution is to set the Dynaserv drive to the same resolution as the OEM070 with the Dynaserv "on board" multiplier.
Add Comment