Frame sizes 1 & 2 do not have an option call out for a contactor option. These sizes always include an AC contactor for the in-coming AC power. (for example - 955+8R0020)
Frame sizes 1 & 2 do not have an option call out for a contactor option. These sizes always include an AC contactor for the in-coming AC power. (for example - 955+8R0020)
Frame size 3 does not have a call out for a DC contactor. If no option is specified it will always include the DC contactor for the motor armature circuit (for example - 955+8R0150)
Frame size 3 does offer an AC contactor option instead of the DC contactor. This would be called out with the -A3 option at the end of the part number (for example - 955+8R0150-A3)
Frame size 4 has a call out for either option. Use the call out -A4 or -D4, to specify whether an AC contactor or a DC contactor is included. (for example - 955+8R0200-A4 or 955+8R0200-D4)
glh Nov 2020
Frame size 3 does not have a call out for a DC contactor. If no option is specified it will always include the DC contactor for the motor armature circuit (for example - 955+8R0150)
Frame size 3 does offer an AC contactor option instead of the DC contactor. This would be called out with the -A3 option at the end of the part number (for example - 955+8R0150-A3)
Frame size 4 has a call out for either option. Use the call out -A4 or -D4, to specify whether an AC contactor or a DC contactor is included. (for example - 955+8R0200-A4 or 955+8R0200-D4)
glh Nov 2020