Ordering Code for ACR9000, 9030, 9040, 9600, 9630 and 9640 controllers
Notes:
3:
96xx models are only available with P3 option
P0 and P2 options are no longer available
4:
9040 and 9640 models are only available with U0 option.
9x00, 9x30 must select U2 thru U8
9030 and 9630 models include 16 axes of ETHERNET Powerlink control. However only 16 total axes can be used at one time. For example, with a 9630P3U8 a user could control 4 servos, 4 stepper and 8 EPL axes. With the same controller, the user could alternatively control 7 steppers and 9 EPL axes.
5: M option only available with 9000 models.
6: Analog inputs are only available for 9000 and 9600 models,cannot be combined with ETHERNET Powerlink models
nov 2013 jw
9030P1U2B0 , 9030P1U4B0 , 9030P1U6B0 , 9030P1U8B0 , 9030P3U2B0 , 9030P3U4B0 , 9030P3U6B0 , 9030P3U8B0 , 9040P1U0B0 , 9040P3U0B0 , 9630P3U2B0 , 9630P3U4B0 , 9630P3U6B0 , 9630P3U8B0 , 9640P3U0B0 ,9000P1U2B0 , 9000P1U2B1 , 9000P1U2M0 , 9000P1U2M1 , 9000P1U4B0 , 9000P1U4B1 , 9000P1U4M0 , 9000P1U4M1 , 9000P1U6B0 , 9000P1U6B1 , 9000P1U6M0 , 9000P1U6M1 , 9000P1U8B0 , 9000P1U8B1 , 9000P1U8M0 , 9000P1U8M1 , 9000P3U2B0 , 9000P3U2B1 , 9000P3U2M0 , 9000P3U2M1 , 9000P3U4B0 , 9000P3U4B1 , 9000P3U4M0 , 9000P3U4M1 , 9000P3U6B0 , 9000P3U6B1 , 9000P3U6M0 , 9000P3U6M1 , 9000P3U8B0 , 9000P3U8B1 , 9000P3U8M0 , 9000P3U8M1 , 9600P3U2B0 , 9600P3U2B1 , 9600P3U4B0 , 9600P3U4B1 , 9600P3U6B0 , 9600P3U6B1 , 9600P3U8B0 , 9600P3U8B1