IPA Troubleshooting - ETT Actuator Noise
As the analog hall sensors are used for position feedback, set LOPASS. A good value for most applications will be 200Hz. Set this in a PBOOT program so that it's set every time on power-up or set it within the defines.
LOPASS X 200Â Â Â Â Â Â Â Â : REMÂ This is p12386, lopass filter (frequency cutoff in Hertz)
Â
Unloaded ETT025-S2 with 150mm stroke Tuning gains:
PGAIN X 0.001Â Â Â Â Â Â Â : REM Proportional Gain
DGAIN X 0.00001Â Â Â : REM Derivative Gain
Â
Note the pitch distance (1 electrical cycle = 2 motor poles) = 60mm on all of the ETTs and the encoder resolution (ERES) is 4096 counts over that distance. These are already set in the IPA in the motor configuration file.
Â
Â
As of version 6.4.1 of ACR-View the Auto Inertia detection within the Configuration Wizard for the ETT does not work.Â
6/10/16jh