  1. Open ACR-View. Create a project with an AriesController AR-xxCE, or open an existing AriesController project. 

In the Project Workspace the AriesController (default name ARxxCE), set the IP address for the unit.

Default is 192.168.100.x   --where x is the address based on the dial switches on the front of the AriesControllerie,   if   x1 is 1, x10 is 0, then the ip address of the AriesCE is 192.168.100.1

ce_to_epl0_3351-20240521-000953.jpg

 

  1. Then click connect. The AriesCE auto-detects straight-through or crossover cable.

Note:  the PC's IP address should be set to 192.168.100.x  --where x is something different than the AriesCE address or other devices on the network.

This is set in Start Menu > Control Panel > Network and Internet > Network and Sharing Center > Local Area Connection > Properties > Internet Protocol Version 4 (TCP/IPv4) > Properties > Use the following IP address:

Subnet mask should be set to 255.255.255.0

Leave Default gateway: blank.

If connection is succesful, ACR-View shows this in the message box below:

1b_3352-20240521-000953.jpg

  1. Tools > OS Update >

  2. Click Update ACR OS...

  3. Navigate to the AriesEPL .ops firmware file.

These files (latest version and previous)  are on our website here:

http://www.parkermotion.com/scripts/support_downloads.asp#APOS

  1. ACR-View will perform a FLASH RES to clear system memory.

2b_3353-20240521-000953.jpg

  1. OS will be saved to flash memory:

3b_3354-20240521-000953.jpg

  1. Status: Download successfully completed.  Reboot Controller:

6b_3355-20240521-000953.jpg

  1. After reboot, the unit is now an AriesEPL which does not have a TCP/IP port connection and thus, you will get Error: Rebooting Controller TimeOut from ACR-View.

You may now connect it to an ACR9000-EthernetPowerlink controller (ACR9030, ACR9040) or ACR9600-EthernetPowerlink controller (ACR9630, ACR9640) to the EPL port to configure in ACR-View with that controller's project. Use the configuration wizard to download the motor configuration through the ACR9000 controller to the AriesEPL drive.

7b_3356-20240521-000953.jpg

 

Related FAQ:   How to Convert an AriesPE (AriesEPL) to AriesCE

 