How to Convert an AriesCE to AriesPE (AriesEPL)
Open ACR-View. Create a project with an AriesController AR-xxCE, or open an existing AriesController project.Â
In the Project Workspace the AriesController (default name ARxxCE), set the IP address for the unit.
Default is 192.168.100.x  --where x is the address based on the dial switches on the front of the AriesControllerie,  if  x1 is 1, x10 is 0, then the ip address of the AriesCE is 192.168.100.1
Â
Â
Then click connect. The AriesCE auto-detects straight-through or crossover cable.
Note: the PC's IP address should be set to 192.168.100.x --where x is something different than the AriesCE address or other devices on the network.
This is set in Start Menu > Control Panel > Network and Internet > Network and Sharing Center > Local Area Connection > Properties > Internet Protocol Version 4 (TCP/IPv4) > Properties > Use the following IP address:
Subnet mask should be set to 255.255.255.0
Leave Default gateway: blank.
If connection is succesful, ACR-View shows this in the message box below:
Â
Tools > OS Update >
Click Update ACR OS...
Navigate to the AriesEPL .ops firmware file.
These files (latest version and previous)  are on our website here:
http://www.parkermotion.com/scripts/support_downloads.asp#APOS
ACR-View will perform a FLASH RES to clear system memory.
Â
OS will be saved to flash memory:
Â
Status: Download successfully completed. Reboot Controller:
Â
After reboot, the unit is now an AriesEPL which does not have a TCP/IP port connection and thus, you will get Error: Rebooting Controller TimeOut from ACR-View.
You may now connect it to an ACR9000-EthernetPowerlink controller (ACR9030, ACR9040) or ACR9600-EthernetPowerlink controller (ACR9630, ACR9640) to the EPL port to configure in ACR-View with that controller's project. Use the configuration wizard to download the motor configuration through the ACR9000 controller to the AriesEPL drive.
Â
Â
Related FAQ:Â Â How to Convert an AriesPE (AriesEPL) to AriesCE