Compax Replacements
Single Axis Compax Drives:
 | COMPAX1000SL | COMPAX2500S | COMPAX4500S | COMPAX8500S |
Continuous Current | 2.5A | 6.3A | 6.5A | 12.5A |
Peak Current | 5.0A | 12.6A | 13.0A | 25.0A |
Input Mains Voltage | 120-230vac, 1phase | 120-230vac, 1 or 3phase | 230-460VAC, 3phase | 230-460VAC, 3phase |
Input Control Voltage | 24vdc | 24vdc | 24vdc | 24vdc |
W X H X D (mm) | 85 x 206.5 x 145.5 | 130 x 290 x 221 | 145 x 395 x 275 | 145 x 395 x 275 |
Suggested C3 Replacement | S025V2F10I11T30M00 | S063V2F10I11T30M00 | S075V4F10I11T30M00 | S150V4F10I11T30M00 |
Multi Axis Compax Drives:
 | COMPAX200M | COMPAX500M | COMPAX1500M | COMPAX3500M |
Continuous Current | 6.5A | 11.5A | 25A | 50A |
Peak Current | 8.5A | 17A | 50A | 100A |
Voltage | 140-650VDC from NMD Power Supply | |||
Suggested C3 Replacement | M100D6F10I11T30M00 | M150D6F10I11T30M00 | M300D6F10I11T30M00 | H050V4F10I11T30M00* @ 400vac or H090V4F10I11T30M00* for 480vac |
*Compax3H series is a High Powered single axis drive and not used with the C3M power supplies.
Above are base servo amplifiers only capable of analog torque, analog velocity, step & direction and encoder following modes. For the 30M, 60M and 70M options:
Technology Levels:
COMPAX xx30M: Indexing table control | Standard Compax3 T11, T30 and T40 capable of Load Mounted Feedback |
COMPAX xx60M: Electronic gearing | Compax3 T30 |
COMPAX xx70M: Cam Control | Compax3 T40 |
Example: COMPAX2570S would be replaced with the S063V2F10I11T40M00
 | NMD10 | NMD20 |
Input Mains Voltage | 100-480VAC 3phase | 100-480VAC 3phase |
Input Control Voltage | 24vdc | 24vdc |
Continuous Power | 10kW | 10kW |
Peak Power (<3sec) | 20kW | 20kW |
Suggested C3 Replacement | MP10D6USBM00NA | MP20D6USBM00NA |
Options | Description | Suggested C3 Replacement |
A1 | Absolute Encoder | SSI Encoder input on x11 on Standard Compax3. HEDA is M10/M11 option. |
D1 | D-to-A monitor w/o box | Standard Compax3 has 2 analog outputs. |
E2 | Encoder input module (individual unit) | Standard Compax3 has encoder input. |
E3 | Encoder simulation output | Standard Compax3 has encoder output. |
E4 | Encoder input module (encoder bus) | Standard Compax3 has encoder input. HEDA is M10/M11 option. |
E7 | Analog input module | Standard Compax3 has 2 analog inputs. |
F1 | RS485, 4 wire | Standard Compax3 |
F2 | Interbus-S | No offering |
F3 | Profibus | Standard Compax3 with I20 |
F4 | CAN bus (BasicCAN protocol as per specification 1.2) | No offering |
F5 | RS485, 2 wire | Standard Compax3 |
F7 | C31System Bus - ABB interface. | No offering |
F8 | CAN open (Protocol as per CiA DS 301. Profile CiA DS 402 for drives.) | Standard Compax3 with I21 |
S1Â | SinCos encoder (single turn) | Standard Compax3 with F11 |
S2 | SinCos encoder (multi turn) | Standard Compax3 with F11 |
S3 | Linear motor support | Standard Compax3 with F12 |
Above are suggested replacements. Applications should be reviewed by your local Parker Automation Technology Center to insure replacement products have all features being used in the machine application.
Related FAQ:Â Connecting Compax resolver feedback cable to Compax3
06FEB2019 12:56 DCLIFFE -- Fixed link.