Updated Control Terminal Torque Specifications for AC10 VFDs
It has been determined that the AC10 control terminal torque specification of 0.6Nm in the product manuals for both the IP20 and IP66 (NEMA4X) versions is incorrect. The correct control terminal torque specifications are as follows:
          Â
IP20 Version P/N’s beginning 10G-
           Frame 1                        0.2Nm
           Frames 2 & larger         0.4Nm
Â
IP66 (NEMA4X) Version P/N’s beginning 16G-
           All Frames                    0.4Nm
Â
Â
Â
glh 9/2020