The Compax3 can be powered with DC voltage (no hardware changes necessary) and is now released and available.
This gives a compatible servo drive with I30 EthernetPowerlink option available in addition to other field bus options (I20 Profibus, I21 CANopen, I22 DeviceNet, I31 EtherCAT, I32 ProfiNet) or an alternative to the ViX (AH/IH) drives.
MX80 motor selections in C3 Servo manager can be found under the Parker Europe motor list.
NOTE!!!!. When using MX80 you can NOT apply AC voltage to the drive. You will need to connect 80VDC or less to connector X1. If the DC supply voltage is lower than 70V, the Error Reaction (3222) to "Bus Voltage Too Low" must be deactivated.