Updated EPL Network Flags and Parameters
Supplement to ACR User Guide- Supersedes ACR Parameter and Bit Reference  88-025605-01H  10/2010
 Products: ACR9000,9030,9040,9600,9630,9640
Â
Operating System | Features Added |
 |  |
ACR90xx 1.28/IEC96xx 2.28 | P37378-37383 Bit 2-3,18-19 |
Â
Bit16640--Bit16660 EPL Network Flags | Â | ||||||||
 |  |  |  |  |  |  |  |  |  |
Code-0xD2; Index=0x00 | Â | P4616 | Â | Â | |||||
EPL Network Control Parameters | Bit Index | Bit Number | Â | ||||||
 | |||||||||
Start Network | 0 | 16640 | Â | Â | |||||
Reset Network | 1 | 16641 | Â | ||||||
SDO Send Request | 2 | 16642 | Â | ||||||
SDO Read Request | 3 | 16643 | Â | ||||||
Reserved | 4-7 | 16644-16647 | Â | ||||||
EPL Controller Installed | 8 | 16648 | Â | ||||||
Network Operational | 9 | 16649 | Â | ||||||
Network Start Failed | 10 | 16650 | Â | ||||||
EPL Node Failure | 11 | 16651 | Â | ||||||
EPLD Stream Open | 12 | 16652 | Â | ||||||
EPLD Stream Disconnected | 13 | 16653 | Â | ||||||
EPL Drive(s) Enabled | 14 | 16654 | Â | ||||||
Insufficient Period | 15 | 16655 | Â | ||||||
Starting Network | 16 | 16656 | Â | ||||||
Resetting Network | 17 | 16657 | Â | ||||||
Writing SDO Data | 18 | 16658 | Â | ||||||
Reading SDO Data | 19 | 16659 | Â | ||||||
Opening EPLD Stream | 20 | 16660 | Â | ||||||
 |  |  |  |  |  |  |  |  |  |
Field Description | Read/Write | Description | Â | ||||||
 | |||||||||
Start Network | R/W | Set the bit to start the EPL network. The Managing Node (MN) places the Controlled Nodes (CN) into a pre-operational state, configures the CNs, then places the CNs into an operational state. The bit is self-clearing. | Â | ||||||
Reset Network | R/W | Set the bit to reset the EPL network to a non-operational state. The bit is self-clearing. | Â | ||||||
SDO Send Request | R/W | Setting the bit sends SDO data specified in P37378-37381. The bit is self-clearing. | Â | ||||||
SDO Read Request | R/W | Setting the bit reads SDO data specified in P37378-37381. The bit is self-clearing. | Â | ||||||
EPL Controller Installed | R | EPL controller card has been detected. | Â | ||||||
Network Operational | R | The EPL controller is exchanging data with the drives. | Â | ||||||
Network Start Failed | R | An attempt to start the network using bit 16640 has failed. To determine why the attempt failed, look at P37384-P37386. | Â | ||||||
EPL Node Failure | R | An individual EPL node has failed. To determine which node failed, look at P37385 | Â | ||||||
EPLD Stream Open | R | An EPLD stream is open (using the OPEN command). To determine which EPL drive is communicating, and its device number, look at P37387 and P37388 | Â | ||||||
EPLD Stream Disconnected | R | Set when an unexpected disconnection with an EPL drive occurs. The controller automatically closes the EPL communication stream. | Â | ||||||
EPL Drive(s) Enabled | R | The controller will not allow the network to be started or reset if any of the EPL drives are enabled. | Â | ||||||
Insufficient Period | R | Set when the period is too low. Network will not start. | Â | ||||||
Starting Network | R | Indicates that a network start is underway. | Â | ||||||
Resetting Network | R | Indicates that a network reset is underway. | Â | ||||||
Writing SDO Data | R | Indicates that a SDO write is in process. | Â | ||||||
Reading SDO Data | R | Indicates that a SDO read is in process. | Â | ||||||
Opening EPLD Stream | R | Indicates that the process of opening an EPLD stream is underway. | Â |
Â
P37376 - P37391 EPL Network Parameters |  | ||||||||
 |  |  |  |  |  |  |  |  |  |
Code-0xD2; Index=0x00 | Â | Â | Â | Â | Â | Â | Â | Â | Â |
EPL Network Control Parameters | Data Type | P |  |  | |||||
 | |||||||||
Number of controlled nodes (CN) | Long | 37376 | Â | ||||||
Reserved | Long | 37377 | Â | ||||||
Node ID for SDO transfer | Long | 37378 | Â | ||||||
Index # for SDO transfer | Long | 37379 | Â | ||||||
Sub-index # for SDO transfer | Long | 37380 | Â | ||||||
Type of data for/from SDO transfer | Long | 37381 | Â | ||||||
Expected length (bytes) of transfer | Long | 37382 | Â | ||||||
Actual length (bytes) of completed transfer | Long | 37383 | Â | ||||||
 |  |  |  |  |  |  |  |  |  |
Field Description | Read/Write | Description | Â | ||||||
 | |||||||||
Number of Controlled Nodes (CN) | R/W | Sets the number EPL drives (called controlled nodes) in the network. Saved via ESAVE command | Â | ||||||
Node ID for SDO transfer | R/W | Specifies the Node ID of the device targeted for subsequent SDO transfers | Â | ||||||
Index # for SDO transfer | R/W | Index number of the Object Dictionary entry to be read/written. Must be integer value | Â | ||||||
Sub-index # for SDO transfer | R/W | Sub-Index number of the Object Dictionary entry to be read/written. Must be integer value | Â | ||||||
Type of data for/from SDO transfer | R/W | EPL DataType of Object to be transferred | Â | ||||||
Expected length (bytes) of transfer | R/W | For string data types only, parameter indicates expected length in bytes of the data to be transferred | Â | ||||||
Actual length (bytes) of completed transfer | R | Number of bytes exchanged in last SDO transfer |  |